Flow measurement

  • Four-path Gas Ultrasonic Flow Meter
    SPECIFICATIONS Senior Sonic 3414
  • Velocity Range: 0 to 30 m/s
  • Meter Performance: Flow calibrated accuracy is ±0.1% of reading relative to lab over entire flow calibration range
  • Repeatability: ±0,05% of reading for 1,5 to 30,5 m/s
  • Line Sizes:100 to 1050 mm
  • Operating Pressure Range (Transducers): 689 to 27,579 kPa-g
  • Operating Temperature: -40°C to 60°C
  • Power: 10.4 VDC to 36 VDC
  • Certifications: Explosive Atmospheres (ATEX)
  • Certifications: MID, TCM
  • Data sheet - pdfGas USM 3414

  • Flow measurement - SPECIFICATIONS - Floboss 103
  • Mass flow accuracy: ±0,075% of span
  • Stability: ±0,1% z URL for 12 months
  • Rangetown: Differential pressure: 10:1 | Absolute pressure: 5:1
  • Pressure ranges: Differential pressure: 0 - 62,2 kPa | Absolute pressure: 0 - 25 MPa
  • Operating Temperature: -40°C to +85°C
  • Output: 4-20 mA - RS 232 or RS 485
  • Certifications: Atex
  • Data sheet - pdfFloboss103

  • Flow measurement liquid (water) and gas - SPECIFICATIONS - Vortex 8800D
  • Mass flow accuracy: for liquid: ±0,65% of flow rate | for gases and steam: ±1,35% of rate
  • Stability: ±0,1% z URL for 12 months
  • Repeatability: ±0,1%
  • Pressure ranges: 2 kPa to 69 MPa
  • Process connection: ANSI: Class 150 - Class 1500 | DIN: PN16 - PN160 | JIS: 10K - 40K
  • Temperature process fluids: -40°C to 454°C
  • Output: 4-20 mA + HART or Fieldbus
  • Certifications: Atex
  • Data sheet - pdfVortex8800D

  • Flow measurement - SPECIFICATIONS - 3051SFC
  • Mass flow accuracy: ±0,75% of flow rate
  • Stability: 5 years
  • Rangetown: 8:1
  • Repeatability: ±0,1%
  • Immersion lenght: 15 mm - 200 mm
  • Temperature process fluids: to 454°C
  • Process connection: ANSI: Class 150 - Class 600 | DIN: PN16 - PN100 | JIS: 10K - 40K
  • Output: 4-20 mA + HART or Fieldbus
  • Certifications: Atex
  • Data sheet - pdf3051_SFC

  • Flow measurement - SPECIFICATIONS - 3051SFA
  • Mass flow accuracy: ±0,9% of flow rate
  • Rangetown: 8:1
  • Repeatability: ±0,1%
  • Immersion lenght: 50 mm - 1800 mm
  • Temperature process fluids: -40°C to 454°C
  • Process connection: ANSI: Class 150 - Class 2500 | DIN: PN16 - PN100
  • Output: 4-20 mA + HART or Fieldbus
  • Certifications: Atex
  • Data sheet - pdf3051SFA

  • Flow measurement - SPECIFICATIONS - 3095MFA
  • Mass flow accuracy: ±0,9% of flow rate
  • Rangetown: 8:1
  • Repeatability: ±0,1%
  • Immersion lenght: 50 mm - 2400 mm
  • Temperature process fluids: -40°C to 454°C
  • Process connection: ANSI: Class 150 - Class 2500 | DIN: PN16 - PN100
  • Output: 4-20 mA + HART or Fieldbus
  • Certifications: Atex
  • Data sheet - pdf3051MFA

  • Flow measurement - SPECIFICATIONS - Annubar 485
  • Mass flow accuracy: ±0,75% of flow rate
  • Repeatability: ±0,1%
  • Immersion lenght: 50 mm - 2400 mm
  • Temperature process fluids: -40°C to 677°C
  • Process connection: ANSI: Class 150 - Class 2500 | DIN: PN16 - PN100
  • Data sheet - pdfAnnubar485

  • SPECIFICATIONS - Magnetic Flowmeter 8705
  • Mass flow accuracy: ±0,5% of rate
  • Flow rate range: od 0,3 to 10 m/s
  • Rangetown: 8:1
  • Compatibility: with Rosemount 8712D, 8732E and 8742C transmitters
  • Line sizes: 15 mm - 900 mm
  • Temperature process fluids: -29°C to 177°C
  • Resistance to immersion: to 10 meters, IP 68
  • Process connection: ANSI: Class 150 - Class 300 | DIN: PN10 - PN40
  • Data sheet - pdf8700

  • SPECIFICATIONS - Magnetic Flowmeter 8707
  • Mass flow accuracy: ±0,5% of rate
  • Flow rate range: od 1 to 10 m/s
  • Rangetown: 8:1
  • Compatibility: with Rosemount 8712D/H, 8732E and 8742C transmitters
  • Line sizes: 80 mm - 600 mm
  • Temperature process fluids: -29°C to 177°C
  • Resistance to immersion: to 10 meters, IP 68
  • Process connection: ANSI: Class 150 - Class 900 | DIN: PN10 - PN40
  • Data sheet - pdf8700

  • SPECIFICATIONS - Magnetic Flowmeter 8711
  • Mass flow accuracy: ±0,5% of rate
  • Flow rate range: od 1 to 10 m/s
  • Compatibility: with Rosemount 8712D, 8732E and 8742C transmitters
  • Line sizes: 15 mm - 200 mm
  • Temperature process fluids: -29°C to 177°C
  • Resistance to immersion: to 10 meters, IP 68
  • Process connection: ANSI: Class 150 - Class 300 | DIN: PN10 - PN25
  • Data sheet - pdf8700

  • SPECIFICATIONS - Magnetic Flowmeter 8721 (Sanitary Flowtube)
  • Mass flow accuracy: ±0,5% of rate
  • Flow rate range: od 0,01 to 10 m/s
  • Compatibility: with Rosemount 8712D, 8732E and 8742C transmitters
  • Line sizes: 15 mm - 200 mm
  • Temperature process fluids: -29°C to 177°C
  • Resistance to immersion: to 10 meters, IP 68
  • Process connection: Tri-Clamp (Sanitary Coupling) | Weld Nipple | DIN 11851 | DIN 11864 | SMS 1145
  • Data sheet - pdf8700

  • Transmitter - SPECIFICATIONS - 8712D/H
  • Flowtube coil resistance: 8712D: 350 | Ohm 8712H: 12 Ohm
  • Flow rate range:  8712D: 0 - 12 m/s | 8712H: 0,01 - 10 m/s
  • Stability: ±0,1% of rate over 6 months
  • Repeatability: ±0,1%
  • Compatibility: 8712D: with Rosemount 8705, 8707, 8711 and 8721 | 8712H: only with Rosemount 8707
  • Teplotní rozsah: 8712D: -29°C to 60°C | 8712D: -29°C to 60°C
  • Data sheet - pdf8700

  • Transmitter - SPECIFICATIONS - 8732E/8742C
  • Flowtube coil resistence: 25 Ohm maximum
  • Flow rate range:  8732E: 0,01 - 10 m/s | 8742C: 0 - 12 m/s
  • Stability: ±0,1% of rate over 6 months
  • Repeatability: ±0,1%
  • Compatibility: with Rosemount 8705, 8711 and 8721
  • Temperature process fluids: -40°C to 74°C
  • Data sheet - pdf8700

  • Transmitter - SPECIFICATIONS - RFT9739
  • Works with Micro Motion senzors: H, F, ELITE
  • Output: 4 - 20 mA + HART or Modbus | equency output (active 0 to 15V, pasive 0 to 30V) | dDual-channel frequency output
  • Communication: Bell 202 | RS-485
  • Data sheet - pdfRFT9739

  • Transmitter - SPECIFICATIONS - série 1000 a 2000
  • Works with Micro Motion senzors:  R, F, T, ELITE
  • Compact control:  integral mounting to sensor | sensor with 360 degrees of rotation | Dual line display for process variables and totalizer reset
  • Output: 4 - 20 mA + HARD, Fieldbus or Modbus | Frequency/pulse output | RS485
  • Data sheet - pdf1000 a 2000

  • Transmitter - SPECIFICATIONS - série 3000
  • Works with Micro Motion senzors:  R, T, H, F, ELITE
  • Large operator interface for easy setup adn control: 128 x 128 pixel display enhances view of process
  • Mass flow accuracy: for liquids: ±0,5% of flow rate  | for gas: ±0,5% of flow rate | Density accuracy: ±0,3%
  • Easy to read menus and advanced help system
  • Output: 4 - 20 mA + HART or Fieldbus
  • Data sheet - pdf3000

  • SPECIFICATIONS LF-senzor
  • Maximum flow range: 27 kg/h
  • Mass flow accuracy: for liquids: ±0,5% of flow rate  | for gas: ±0,5% of flow rate | Density accuracy: ±0,3%
  • Repeatability: for liquids: ±0,5% | for gas: ±0,5%
  • Temperature process fluids: 0°C to 65°C
  • Certifications: Atex
  • Data sheet - pdfLF-senzor

  • SPECIFICATIONS R-senzor
  • Maximum flow range: 87 100 kg/h
  • Mass flow accuracy: for liquids: ±0,50% of flow rate | for gas: ±0,75% of flow rate
  • Repeatability: for liquids: ±0,5% | for gas: ±0,5%
  • Temperature process fluids: -50°C to 150°C
  • Certifications: Atex
  • Data sheet - pdfR-senzor

  • SPECIFICATIONS T-senzor
  • Maximum flow range: 87 100 kg/h
  • Mass flow accuracy: for liquids: ±0,15% of flow rate | for gas: ±0,5% of flow rate | Density accuracy: ±2,0kg/m3
  • Repeatability: ± 0,05%
  • Temperature process fluids: -50°C to 150°C
  • Certifications: Atex
  • Data sheet - pdfT-senzor

  • SPECIFICATIONS H-senzor
  • Maximum flow range: 272 160 kg/h
  • Mass flow accuracy: for liquids: ±0,15% of flow rate | for gas: ±0,50% of flow rate | Density accuracy: ±2,0kg/m3
  • Repeatability: for liquids: ±0,10% | for gas: ±0,25%
  • Temperature process fluids: -100°C to 180°C
  • Certifications: Atex
  • Data sheet - pdfH-senzor

  • SPECIFICATIONS F-senzor
  • Maximum flow range: 272 160 kg/h
  • Mass flow accuracy: for liquids: ±0,20% of flow rate | for gas: ±0,50% of flow rate | Density accuracy: ±2,0kg/m3
  • Rangetown: 20:1
  • Repeatability: for liquids: ±0,10% | for gas: ±0,25%
  • Temperature process fluids: -100°C to 180°C
  • Certifications: Atex
  • Data sheet - pdfF-senzor

  • SPECIFICATIONS ELITE/CMF
  • Maximum flow range: 545 500 kg/h
  • Mass flow accuracy: for liquids: ±0,10% of flow rate | for gas: ±0,35% of flow rate | Density accuracy: ±0,5kg/m3
  • Repeatability: for liquids: ±0,05% | for gas: ±0,25%
  • Temperature process fluids: -240°C to 204°C
  • Certifications: Atex
  • Data sheet - pdfELITE-CMF