Level measurement

  • Level measurement - SPECIFICATIONS 3051 L
  • Accuracy: ±0,075% of span
  • Stability: ±0,125% z URL for 5 years
  • Rangetown: 100:1
  • Pressure range: 0,65 kPa - 2070 kPa
  • Number of ranges: 3
  • Ambient temperature: -40°C to +85°C
  • Temperature process fluids:: -40°C to +121°C
  • Output: 4-20 mA + HART or Fieldbus
  • Overpressure limit: meadly type of collar
  • Certifications: Atex
  • Data sheet - pdf3051

  • Level measurement - SPECIFICATIONS 3051S L
  • Accuracy: ±0,065% of span
  • Stability: 10 years
  • Rangetown: 100:1
  • Pressure range: 0,12 kPa - 13,8 MPa
  • Number of ranges: 5
  • Ambient temperature: -40°C to +85°C
  • Temperature process fluids:: -40°C to +121°C
  • Output: 4-20 mA + HART or Fieldbus
  • Overpressure limit: meadly type of collar
  • Certifications: SIS, Atex
  • Data sheet - pdf3051

  • Series 2051 Level measurement - SPECIFICATIONS 2051 L
  • Accuracy: ±0,075% of span
  • Stability: ±0,125% z URL for 2 years
  • Rangetown: 100:1
  • Pressure range: -62,2 kPa - 2068 kPa
  • Number of ranges: 3
  • Ambient temperature: -40°C to +85°C
  • Temperature process fluids:: -40°C to +121°C
  • Output: 4-20 mA + HART or Fieldbus
  • Overpressure limit: meadly type of collar
  • Certifications: Atex
  • Data sheet - pdf2051

  • Level measurement - SPECIFICATIONS 2110
  • Measurement Principle: Vibrating Fork
  • Maximum Operating Pressure: Final rating depends on tank connection
  • Minimum Liquid Density: 600 kg/m3
  • Pressure range: -62,2 kPa - 2068 kPa
  • Liquid Viscosity Range: 0,2 to 10 000 cP
  • Electrical Connections: Direct load switching: =21V to =264V a ~21V to ~264V (50 Hz/60 Hz) | Solid state PNP output: =18 V to =60 V
  • Process connection: two wire | three wire
  • Temperature process fluids: -40°C to +150°C
  • Certifications: Atex
  • Data sheet - pdf2110

  • Level measurement - SPECIFICATIONS 2120
  • Measurement Principle: Vibrating Fork
  • Maximum Operating Pressure: Final rating depends on tank connection
  • Minimum Liquid Density: 600 kg/m3
  • Liquid Viscosity Range: 0,2 to 10 000 cP
  • Switching Delay: 0,3; 1; 3; 10; 30 s
  • Electrical Connections: Direct load switching: =20V to =60V and ~20V to ~264V (50 Hz/60 Hz) | Solid state PNP output: =20 V to =60 V | SPCO single relay: =Umax 60V and ~Umax 250V | Intrinsically Safe NAMUR
  • Process connection: two wire | three wire
  • Temperature process fluids: -40°C to +150°C
  • Certifications: Atex
  • Data sheet - pdf2120

  • Float Level Sensor
  • Accuracy: ±0,25% of span
  • Output: 4-20 mA + HART or Fieldbus
  • Temperature process fluids: +427°C
  • Velikost připojení: ANSI: Class 150 - Class 2500 | DIN: PN10 - PN250
  • Certifications: Atex
  • Data sheet - pdfFieldvue

  • Ultrasonic Level Transmitter - SPECIFICATIONS 3100
  • Measurement Principle: Ultrasonic, time-of-flight
  • Reference Accuracy: ±0.25% of measured distance
  • Measurement Range: 0,3 m to 11 m
  • Update Interval: 1 second
  • Ambient temperature: -40°C to +70°C
  • Temperature process fluids: -30°C to +70°C
  • Output: 4-20 mA + HART
  • Certifications: Atex
  • Data sheet - pdf3100

  • Ultrasonic Level Transmitter - SPECIFICATIONS 3300
  • Accuracy: ±5 mm for sensors < 5 m
  • Repeatability: ±1 mm
  • Measurement Range: od 0,4 m to 23,5 m
  • Microwave Output Power: Nominal: 50 µW | Max. výkon: 2 mW
  • Start-up Time:  <1 per second
  • Output: 4-20 mA + HART
  • Ambient temperature: -40°C to +85°C
  • Temperature process fluids:: -40°C to +121°C
  • Overpressure limit: meadly type of collar
  • Certifications: SIS, Atex
  • Data sheet - pdf3300

  • Ultrasonic Level Transmitter - SPECIFICATIONS 5300
  • Measurement Principle: Time Domain Reflectometry (TDR)
  • Microwave Output Power: Nominal 300 µW, Max. 45 mW
  • Reference Accuracy: ±0.03% of measured distance
  • Update Interval: < 1 per second
  • Measurement Range: 0.4 m to 50 m
  • Ambient temperature: -40°C to +80°C
  • Temperature process fluids: -60°C to +400°C
  • Output: 4-20 mA + HART or Fieldbus
  • Certifications: Atex
  • Data sheet - pdf5300

  • Ultrasonic Level Transmitter - SPECIFICATIONS 5401/5402
  • Measurement Principle: Pulsed, free propagating radar
  • Frequency version: 5402: 26 GHz | 5401: 6 GHz
  • Reference Accuracy: 5402: ±3 mm | 5401: ±10 mm
  • Measurement Range: 0.04 m to 35 m
  • Resolution: 1 mm
  • Ambient temperature: -40°C to +80°C
  • Temperature process fluids: 150°C
  • Output: 4-20 mA + HART or Fieldbus
  • Certifications: Atex
  • Data sheet - pdf5400

  • Ultrasonic Level Transmitter - SPECIFICATIONS 5600
  • Measurement Principle: Pulsed, free propagating radar
  • Frequency version: 10GHz
  • Reference Accuracy: ±5 mm
  • Measurement Range: 0.04 m to 35 m
  • Resolution: 1 mm
  • Update Interval: 100 ms
  • Temperature process fluids: -40°C to +400°C
  • Output: 4-20 mA + HART or Fieldbus
  • Certifications: Atex
  • Data sheet - pdf5600

pemit en middle